Short answer: When you replace a water heater in a California home, the 2025 Title 24 Energy Code gives four prescriptive options: a natural gas or propane water heater; a heat pump water heater with a communication port and, where it sits on a surface, an insulated base; a heat pump water heater rated NEEA Tier 3 or higher; or, when replacing an electric-resistance unit, a consumer electric water heater. Accessible hot-water pipes must be insulated. Your building department decides what permit and documentation it needs.
Need a Title 24 report for your permit?
ADU from $199 · Single-family from $245 · Multifamily from $345 per building. Permit-ready PDF in 2–3 business days, CHEERS-registered where required, two revisions included.
When Title 24 Applies to a Water Heater Replacement
The Energy Code's alteration rules for water heating (§150.2(b)1H) apply whenever a replacement or altered water-heating system or component is installed. A straight swap still counts, so the new unit has to fit one of the options below. Building departments handle the paperwork differently: some ask for a prescriptive compliance form or a Title 24 report with the permit, others do not. See when Title 24 is required for other common triggers.
The details on this page follow the CEC's 2025 single-family water heater alterations guidance.
The Four Prescriptive Options
| Option | What you install | Conditions |
|---|---|---|
| (a) | A natural gas or propane water heater | Pipe insulation and other mandatory rules still apply |
| (b) | A single heat pump water heater with a storage tank | The tank has a communication interface meeting §110.12(a) or an ANSI/CTA-2045-B port; where the unit sits on a surface, an incompressible, rigid insulated surface of at least R-10 |
| (c) | A single heat pump water heater rated NEEA Advanced Water Heater Specification Tier 3 or higher | Check the NEEA tier in the product information |
| (d) | A consumer electric water heater: electric storage, electric instantaneous or heat pump | Only when replacing an existing electric-resistance water heater |
These options are listed in §150.2(b)1Hiii. If none of them fits, or the water heater is part of a bigger remodel, the alteration can use the performance path instead (§150.2(b)2B), where the work is modeled in compliance software; see Title 24 calculations.
Heat Pump Water Heater Conditions
Communication port or NEEA Tier 3 rating
Option (b) needs a unit whose tank has a standardized communication connection: either an interface meeting §110.12(a) or an ANSI/CTA-2045-B port. Option (c) relies instead on the unit's rating under the NEEA Advanced Water Heater Specification, at Tier 3 or higher. Ask your installer which option the chosen model satisfies before you buy it.
Insulated base
Under option (b), a unit that sits on a surface, such as a garage slab, needs an incompressible, rigid insulated surface of at least R-10 beneath it.
Ventilation, room volume and backup heat
A heat pump water heater takes heat from the surrounding air, so the code requires ventilation or a minimum room volume where it is installed (§110.3(c)7B). A small closet may need added ventilation. The 2025 code also requires backup heat for a unit that draws unconditioned air, such as one in a garage, unless its compressor cutoff is below the local Heating Winter Median of Extremes (§110.3(c)7A).
Electrical service
Switching from gas to a heat pump unit can mean adding an electrical circuit. The 30 A circuit for a future heat pump water heater in §150.0(n)1Ai is a new-home requirement; in an existing home, your electrician confirms what the chosen model needs.
Pipe Insulation and Recirculation Controls
Accessible new and existing hot-water pipes must be insulated (§150.0(j)1). In practice that usually means pipe you can reach without opening finished walls, for example near the water heater or in an attic, crawlspace or garage. If the home has a demand recirculation system serving one dwelling unit, it needs manual on/off controls.
Gas or Heat Pump: What to Consider
The state code allows both, so the choice often comes down to the site:
- Location and space: a heat pump unit needs enough room volume or ventilation, and a garage location brings in the backup-heat condition.
- Electrical capacity: a heat pump unit may need a new circuit; a gas unit needs a gas supply and venting that suit the new model.
- Model features: option (b) units need the communication port and, on a surface, the R-10 base; option (c) units need the NEEA Tier 3 rating.
- Local rules: some cities adopt reach codes stricter than the state code, so check with your building department before choosing equipment.
Permits and Documentation
Your building department decides whether a water heater replacement needs a Title 24 form or report with the permit. When the replacement is part of a larger project, such as an HVAC changeout, an addition or a remodel, the water heater is usually included in that project's report. Title24Comply prepares residential Title 24 reports for alterations from your plans, and can cover water heating together with a heat pump or HVAC replacement. Your forms also show whether any field verification applies; see when a HERS rater is needed. For code questions, the CEC's Energy Code Hotline is 800-772-3300.
New Homes and Additions Follow Different Rules
The options above are for replacing a water heater in an existing home. Newly constructed homes (see new construction Title 24) need a circuit of at least 30 A for a future heat pump water heater, and the gas tankless exception was removed in Climate Zones 3, 4, 13 and 14 for homes with heat pump space conditioning. For single-family additions, gas tankless was removed from the prescriptive options; that change does not apply to replacements. See 2025 Title 24 changes and additions and Title 24.
Frequently Asked Questions
Can I replace my gas water heater with another gas water heater?
Yes. A natural gas or propane water heater is one of the four prescriptive options for a replacement. Pipe insulation still applies, and some cities have stricter local rules.
Can I install a gas tankless water heater as a replacement?
Under the state code, yes: the 2025 removal of gas tankless applied to additions, not replacements, so the gas or propane option remains. Check local rules before you buy.
Do I need a Title 24 report to replace a water heater?
It depends on your building department. Some accept a prescriptive form with the permit; a full report is more likely when the work is part of a larger project or uses the performance path.
Can a heat pump water heater go in the garage?
It can, but because it draws unconditioned air, it needs backup heat unless its compressor cutoff is below the local Heating Winter Median of Extremes. The ventilation or room volume rules and, under option (b), the insulated base also apply.